- Temperature range 5°C to 60°C
- Powerful fan motor for forced air circulation to maintain uniform conditions inside chamber
|
- Validation protocol with IQ, OQ, DQ Documentation as per ICH guidelines
|
| |
 |
- Machine filled PUF insulation to eliminate void pockets
- Unique design of thermal barrier for better energy efficiency
Hermetically sealed Compressor with CFC free refrigerant
|
- Microprocessor controller with LED display
- Sensor failure alarm
|
| |
 |
- Digital LED display of Temperature with set, process value & audio visual alarm
- Chamber calibration port on side
- Adjustable trays
- Chamber illumination by UV and / or Fluorescent tubes (Optional)
|
- 24 hours Cyclic timer for regulating illumination conditions (Optional)
- Data logger for 8 Point temperature recording with sensor, printer interface and software (Optional)
- Also available 4” LCD version with additional features
|
| |
 |
- High temperature safety cut off & alarms for high / low set parameters
- Electrical circuit breaker
|
- Time delay for compressor switch on
- Overload cut off relay for compressor
|
| |
 |
| |
 |
| |
| Features of Software complying to 21 CFR part 11 |
- Multiple level alpha numerical password with password ageing
- Electronic signature and menu entered comment
- Secured audit trail report
- Alarm report with mention of alarm condition
- Mean Kinetic Temperature able to be calculated for any days & alarm deviation report
|
- Reports in graphical and tabular form
- Data Stored in PC server with Lan connectivity and can be monitored on any PC with password authentication
- Multi chamber data acquisition on single software
|
| |
| Additional Features for LCD version:- |
- 4 Inch attractive LCD display
- Intelligent Controller helps maintain temperature in case of sensor failure
- Battery Backup for Temperature Controller - 12 V, 7.2 Ah sealed maintenance free, Fully charged battery runs for more than eight hours
- Automatic Calibration of set parameters
- Self-Diagnosis for errors
- Histogram format of 24 hours temperature recording
|
- Power failure and resumption recorded with date and time
- Settable High / low alarm points with date and time
- Memory for storage of up to 1000 records
Centronic interface to record Temperature, Date, & Time by attaching Dot Matrix printer with adjustable print interval
- Alarm on equipment / security gate
- PC communication with RS-485 and software complying to 21 CFR part 11 as per USFDA guidelines
|
| |
| Technical data |
| |
CC - 6 Plus |
CC - 10 Plus |
CC - 12 Plus |
CC - 16 Plus |
CC - 19 Plus |
| Internal Volume (Litres) |
200 |
280 |
370 |
450 |
540 |
| Number of tray |
2 |
3 |
4 |
5 |
6 |
| Internal Dimensions W x D x H (mm) |
660x655x450 |
660x655x650 |
660x655x850 |
660x655x1050 |
660x655x1250 |
| External Dimensions W x D x H (mm) |
800x1095x1020 |
800x1095x1220 |
800x1095x1420 |
800x1095x1620 |
800x1095x1820 |
| Temperature Range & Accuracy |
5°C to 60°C, ± 0.5°C |
| Temperature control |
Microprocessor with PT-100 sensor |
| Display |
1" - 7 Segment, Big Size LED |
| Power Failure Alarm |
Audio Visual Alarm |
| Door Open Alarm |
Audio Alarm in case door open for over one minute |
| Temperature Variation Alarm |
Set Temperature ± 2°C, Audio Visual Alarm |
| Illumination |
8 Watts Fluorescent Lamp |
| Internal Body Material |
Stainless Steel - 304 grade (Standard Models), Stainless Steel - 316 grade (GMP Models) |
| External Body Material |
Powder Coated CRCA Steel (Standard Models), Stainless Steel - 304 grade (GMP Models) |
| Insulation |
70 mm minimum for Body & 80 mm for Door, CFC free polyurethane foam |
| Noise Level |
Less Than 65 db(A) |
| Recommended Voltage Stabilizer |
VS-02 |
VS-02 |
VS-02 |
VS-03 |
VS-03 |
| Electrical |
220-240 volts, 50Hz, Single Phase |
|
| |