| Micro Centrifuges models RM-12C BL & R-12M are ideal for growing routine application in biochemical and clinical labs, for Hematocrit, Corpuscle Percentage contents in blood, Serum analysis and precipitate separation etc. |
| |
 |
- Stable speed output even under unstable voltage conditions
Low sample temperature rise
- High Capacity (R-8C BL / R-8M)
|
- High Speed (RM-12C BL / R-12M)
- Wide variety of rotors & reduction adaptors
|
| |
 |
- Brushless Induction motor with frequency drive
- Microprocessor controller with digital display
|
- Smooth & soft start
- Inverter fault detection with auto shutdown
|
| |
 |
- 7 segment LED display of speed
Digital countdown timer & continuous run
- Dynamic brake for quick deceleration
- Last set parameters recall (Useful for repetitive analysis)
|
- Automatic door opening
- Stainless Steel centrifuge Chamber, easy to clean
|
| |
 |
- Safety lid interlock to prevent lid opening during centrifugation
- Imbalance detection & centrifugation stop with display of error
- Motor overload protection
|
- Gas hinge to prevent door falling
- Emergency lid lock release
|
| |
| Models R-8M & R-12M are advanced versions having
following additional features: |
- Feather touch setting keys
- Alphanumeric LCD display of speed & RCF
|
- Selection of 3 acceleration & deceleration profiles
|
| |
| Technical Data |
| Models |
|
R-8C BL R-8M |
RM-12C BL R-12M |
| Max. Speed |
rpm |
6000 |
16000 |
| Max. RCF |
'g' |
5070 |
16600 |
| Max. Capacity |
ml |
400 |
40 |
| Digital timer range |
Min |
0-59 |
0-15 |
| W x D x H |
Mm |
380x460x305 |
380 x 460 x 305 |
Supply:220-240Volts 50Hz Single Phase. |
| |
|
| |
| Rotors Heads Listing for RM-12C BL / R-12M |
| Models |
Capacity |
Max. Speed RPM |
Max. RCF
'g' |
| RM-1210 |
Micro Hematocrit Rotor for 24 Capillaries (75 X 1 mm) |
12000 |
15300 |
| RM-1211 |
Micro Hematocrit Rotor for 12 capillaries (QBC -II Plus) |
12000 |
15300 |
| RM-1212 |
Heparinized capillary tubes (75mm x 1 mm bore) |
|
|
| RM-1213 |
Reading Device for RM-1210 |
|
|
| |
Angle heads |
| RM-1214 |
10 X 2ml with Glass Tubes & reduction adaptors of 1 ml & 0.5ml |
16000 |
16600 |
| RM-1215 |
24 X 1.5ml with Tapered bottom Polypropylene tubes S. reduction adaptors of 1 ml & 0.4ml |
11850 |
12715 |
| RM-1216 |
8 X 5ml with round bottom Polypropylene tubes & reduction adaptors of 4ml & 2ml |
11850 |
13500 |
| RM-1217 |
4 strips of 8 X 0.2ml (PCR Strip Tubes) |
12000 |
11910 |
|
| |
| Rotor Heads Listing for R-8C BL / R-8M |
| Models |
Capacity |
Max. Speed RPM |
Max. RCF
'g' |
Models |
Capacity |
Max. Speed RPM |
Max. RCF
'g' |
| Swing out Heads (with graduated glass tubes) |
Angle Heads (with polypropylene tubes) |
| R-81 |
16 x 15 ml |
4500 |
3485 |
R-83 |
16 x 15 ml |
5250 |
4280 |
| R-81 A |
12 x 15 ml |
4500 |
3485 |
R-83 A |
12 x 15 ml |
5250 |
4280 |
| R-81 B |
8 x 15 ml |
4500 |
3440 |
R-B3 B |
8 x 15 ml |
6000 |
4700 |
| R-82 |
6 x 50 ml |
4500 |
3530 |
R-84 |
6 x 50 ml |
6000 |
4700 |
| R-82A |
4 x 50 ml |
4500 |
3485 |
R-84 A |
4 x 50 ml |
6000 |
4700 |
| R-90 (with |
4 x 100 ml |
4000 |
2500 |
R-88 |
4 x 100 ml |
6000 |
4550 |
| Biosafety cap] |
|
|
|
R-89 |
24 x 15 ml |
6000 |
5070 |
|
| |
| Reduction Adaptors for R-8C BL / R-8M |
| Models |
Capacity |
R-81 |
R-81 A |
R-81 B |
R-82 |
R-82 A |
R-83 |
R-83 A |
R-83 B |
R-84 |
R-84 A |
R-88 |
R-89 |
R-90 |
| RA-151 |
1 x wintrob |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-152 |
1 x 3ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-153 |
1 x 5ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-154 |
1 x 8ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-155 |
1 x 4ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-156 |
1 x 6ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-157 |
1 x 50ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-158 |
1 x 30ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-160 |
1 x 15ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-166 |
3 x 15ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-501 |
1 x 15 ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-502 |
1 x 30ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| Suitable for Falcon Tubes (without tubes) |
| RA-501 F |
1 x 15ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-1B0F |
1 x 15ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-161F |
1 x 50ml |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| Suitable for Vacutainer Tubes (without tubes) |
| RA-162 |
1 x upto 5ml (75 mm long) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-163 |
1 x upto 6ml (100 mm long) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-164 |
1 x upto 10 ml (100 mm long) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-167 |
4 x upto 6ml (100 mm long) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
| RA-168 |
3 x upto 10 ml (100 mm long) |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|